NB-IoT NPRACH Measurement
R&S
®
CMW-KM300/-KS300
345
User Manual 1178.5689.02 ─ 06
For single-preamble modulation measurements, the measurement interval is comple-
ted when the R&S
CMW has measured one full preamble (four symbol groups). The
preamble length depends on the preamble format, see
For multi-preamble measurements, the measurement interval is completed when the
configured number of preambles has been measured, see
The measurement provides independent statistic counts for modulation results and
power dynamics results. In single-shot mode and with a shorter modulation statistic
count, the modulation evaluation is stopped while the R&S
CMW still continues provid-
ing new power dynamics results.
Remote command:
CONFigure:NIOT:MEAS<i>:PRACh:SCOunt:MODulation
EVM Window Length
Length of the EVM window in samples. The standard (3GPP TS 36.101, annex F)
specifies the window length as a function of the preamble format.
The R&S
CMW uses the "Current" value. This value is linked to the value in the table,
corresponding to the current preamble format.
The window length defines the two sets of "l / h" modulation quantities in the result
tables; see
Chapter 4.2.5, "Calculation of Modulation Results"
The minimum value of one FFT symbol means that EVM
h
equals EVM
l
.
Remote command:
CONFigure:NIOT:MEAS<i>:PRACh:MODulation:EWLength
EVM Window Position
Position of the EVM window used for calculation of the trace results. While result tables
show both the results for low and high EVM window position, the diagram results are
only determined for the selected window position.
Remote command:
CONFigure:NIOT:MEAS<i>:PRACh:MODulation:EWPosition
4.3.4.3
Power Settings
The following parameters configure the power settings of the NB-IoT NPRACH mea-
surement.
Figure 4-14: Power settings
Statistic Count
Defines the number of measurement intervals per measurement cycle. A measurement
cycle is the duration of a single-shot measurement. For continuous measurements, the
measurement cycle is relevant for average results.
GUI Reference
深圳德标仪器
135-1095-0799