Service Call Conditions
Conditions
Error Code
(9-22)
At power on
If there is any problem with the thermistor.
(This detection is also done when the machine comes
back to the normal mode from the Power Saver Mode
Level 2.)
Sub-code 09
Standby mode
If the fusing temperature stays below 80
°
C for more
than 18 seconds when power saver standby
temperature (80
°
C) is selected in Power Saver Mode
Level 1.
Or, if the fusing temperature stays below 145
°
C for
more than 25 seconds when the standby temperature
(145
°
C) is selected in Power Saver Mode Level 1.
Sub-code 05
If the fusing temperature takes more than 40 seconds to
reach 160
°
C from the standby temperature.
Sub-code 02
During
printing
If the fusing temperature stays above 185
°
C for more
than 40 seconds.
Sub-code 01
If the fusing temperature comes below 140
°
C during
printing.
Sub-code 07
After printing
If the fusing temperature takes more than 20 minutes to
go down to below 100
°
C when the machine goes into
the Power Saver Mode Level 1. (When fusing lamp OFF
is selected for Power Saver Mode Level 1.)
Sub-code 03
Either: If the fusing temperature takes more than 20
minutes to go down to below 100
°
C when the machine
goes into the Power Saver Mode Level 1 (when the
power saver standby temperature of 80
°
C is selected
for Power Saver Mode Level 1.)
Or: If the fusing temperature takes more than 5 minutes
to go down to the standby temperature (145
°
C) when
the standby temperature is selected for Power Saver
Mode Level 1.
Sub-code 04
At any time
If the fusing temperature reaches 250
°
C.
Sub-code 08
DETAILED SECTION DESCRIPTIONS
May 22nd, 1995
PRINTING
2-54