System Switch 0A
No
FUNCTION
COMMENTS
0
to
3
Not used
Do not change the settings.
4
Dialing on the ten-key pad
when the handset is off-hook
0: Disabled 1: Enabled
1: The user can dial on the machine’s ten-key pad
when the handset is off-hook.
5
On hook dial
0: Disabled 1: Enabled
0: On hook dial is disabled.
6
Not used
Do not change the settings.
7
System Switch 0B
No
FUNCTION
COMMENTS
0
1
Automatic reset timer
Bit 1 Bit 0 Timer setting
0 0 1 minute
0 1 3 minutes
1 0 5 minutes
1 1 No limit
(1, 1): Automatic reset is disabled.
(Other): The machine returns to the standby mode
when the timer expires after the last operation.
2
3
Power Saver mode timer
Bit 3 Bit 2 Time Limit
0 0 1 minute
0 1 3 minutes
1 0 5 minutes
1 1 No limit
(1, 1): Automatic Power Saver mode is disabled.
(Other): The machine goes into a Power Saver mode
when the timer expires after the last operation.
Cross reference
Power Saver modes: Section 2.3.1
4
to
7
Not used
Do not change the settings.
System Switch 0C
No
FUNCTION
COMMENTS
0
to
3
Original size groups to be used in ADF size detection.
Bit 0 to 2: Not used
Bit 3: A4 or Letter
0: A4, 1: Letter
4
to
7
Not used
Do not change the settings.
SERVICE TABLES AND PROCEDURES
May 22nd, 1995
BIT SWITCHES
4-24