5.5.3. Hot Roller Strippers
I
CAUTION
Be careful not to lose the springs.
5.5.4. Fusing Lamp
I
CAUTION
Be careful not to touch the glass surface.
[A]
[B]
H521R037.wmf
Remove the cleaning felt if it is still in the unit, then remove the strippers.
A: Cleaning Felt
B: Hot Roller Strippers (1 spring each)
[A]
H521R629.wmf
115 V Models
A: Fusing Lamp (2 screws)
[A]
H521R652.wmf
220 V Models
A: Fusing Lamp (2 screws)
May 22nd, 1995
REPLACEMENT AND ADJUSTMENT
FUSING
5 - 17