G3 Switch 09 - Not used (do not change the factory settings).
G3 Switch 0A
FUNCTION
COMMENTS
0
1
Maximum allowable carrier
drop during image data
reception
Bit 1 Bit 0 Value (ms)
0 0 200
0 1 400
1 0 800
1 1 Not used
These bits set the acceptable modem carrier drop time.
Try using a longer setting if error code 0-22 is frequent.
2
Not used
Do not change the settings.
3
4
Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
This bit set the maximum intervals between each EOL
signal (end-of-line) or intervals between each ECM
frame from the other end.
Try using a longer setting if error code 0-21 is frequent.
5
Not used
Do not change the settings.
6
Reconstruction time for the
first line in receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a computer,
there may be a delay in receiving page data after the
local machine accepts set-up data and sends CFR. If
this occurs, set this bit to 1 to give the sending
machine more time to send data.
Refer to error code 0-20.
7
Not used
Do not change the settings.
G3 Switch 0B
FUNCTION
COMMENTS
0
Protocol requirements:
Europe
0: Disabled 1: Enabled
Manually set these bit switches to the appropriate
settings after a country code (System Switch 0F) is
programmed.
1
Protocol requirements:
Norway
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements:
France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
SERVICE TABLES AND PROCEDURES
May 22nd, 1995
BIT SWITCHES
4-42