8000BA(H) - User function 62 settings
Bit 0: Not used
Bit 1: Dialing type 0: Pulse dialing (10 pps), 1: Tone (DTMF) dialing
Bits 2 to 7: Not used
8000BB(H) - PSTN access number for loop start
Access number Hex value to program (BCD)
0 F0
ò
ò
0 F0
00 00
ò
ò
99 99
8000C8 to 8000DB(H) - RTI (Max. 20 characters - ASCII) - Note 1
8000DC to 8000EF(H) - CSI (Max. 20 characters - ASCII)
8000F0 to 80010F(H) - TTI (Max. 32 characters - ASCII) - Note 1
800110(H) - Number of CSI characters (Hex)
Note 1: If the number of characters are less than the maxumum (20 for RTI, 32 for TTI), add
a stop code (FF[H]) after the last character.
800111 to 80011F(H) - Service station’s fax number (Service function 13)
800120 to 80012E(H) - Own fax number (User function 61)
80012F(H) - ID code (low - Hex)
800130(H) - ID code (high - Hex)
800140 to 800146(H) - Last power off time (Read only)
800140(H) - Year (BCD)
800141(H) - Month (BCD)
800142(H) - Day (BCD)
800143(H) - 00: Monday, 01: Tuesday, 02: Wednesday, ....... , 06: Sunday
800144(H) - Hour
800145(H) - Minute
800146(H) - Second
800150(H) - Installed equipment (Read only)
Bits 0-2: Not used
Bit 3: ADF 0: Not installed, 1: Installed
Bit 4: 100 sheet cassette 0: Not installed, 1: Installed
Bits 5-7: Not used
800151(H) - Installed equipment
Bit 0: Not used
Bit 1: Printer interface 0: Not installed, 1: Installed
Bits 2-6: Not used
Bit 7: IC page memory card 0: Not installed, 1: Installed
SERVICE TABLES AND PROCEDURES
May 22nd, 1995
SERVICE RAM ADDRESSES
4-78