ID-No. 9230-070-en
Version 1.14 (2019-05)
Page 61
The following table shows the relationship between power range,
operating point display and output of the converter
SAFERUN
®
CMS-T:
LED color
Status
performance range
output
Min
Max
mA
%
a
red
flashes
0
P
0
4
<0 – 0%
a
red
lights up
P
0
P
min
4 – 5
0 – 6.25%
b yellow
lights up
P
min
P
1
5 – 6
6.25 – 12.5%
c
green
lights up
P
1
P
2
6 – 10
12.5 – 37.5%
d
green
lights up
P
2
P
3
10 – 14
37.5 – 62.5%
e
green
lights up
P
3
P
max
14 – 18
62.5 – 87.5%
f yellow
lights up
P
max
P
4
18 – 19
87.5 – 93.75%
g
red
lights up
P
4
P
5
19 – 20
93.75% - 100%
g
red
flashes
>P
5
20
>100%
In addition, (parameter 132) can use the reading using the table's
accumulated operating cycles (parameter 135), energy consump-
tion (parameter 138), flow rate (parameter 139), hours of opera-
tion (parameter 130), downtime (parameter 131) and failure
times are determined.
NOTE
For more information about tablet with RFID reader
and the
SAFERUN
® software see chapter 3.8.
i