Page 62
Version 1.14 (2019-05)
ID-No. 9230-070-en
6.5.6
Output events
About the output of the converter
SAFERUN
® CMS-T special con-
ditions of the pump fixed impressed currents can be assigned.
This fixed current values can eg. be used for error detection in
process control.
The following parameters are provided for special events:
ID.-#
parameter name
event
default value
mA
2)
260 iErrorStop
pump standstill
3.0
261 iErrorTemp
1)
Error temperature sensor
21.0
262 iErrorSensor
Error magnetic sensor
2.5
263 iErrorKupplungsabriss
Clutch demolition / overload
21.5
265 iErrorKupplungMax
Exceeded rated torque
21
267 IErrorDrehzMin
Speed too low for a reasonable evaluation
3.5
268 IErrorDrehzMax
Speed too high for a reasonable evaluation
20.5
269 IErrorClock
Error Date / Time
-1.0
1)
If over the 4-20 mA signal the temperature is output (output
mode = 10, ID.# 210) can (IERROR Temp, ID.# 201) not be de-
activated by -1.0, the event "Error temperature sensor". In
event of -1.0 21.0 mA is output at an event occurrence.
2)
The permissible value range is from 0-4 mA and 20 to 21.5
mA. The value -1.0 disables the event.
In normal operation (ID.# 210, output mode = 0) is not output a
temperature sensor failure as an event (except min. one of the
parameters 180-184 is in use).