Page 48
Version 1.14 (2019-05)
ID-No. 9230-070-en
Fig. 21 Circuit diagram and terminal assignment
5.5.2.3
HART Loop Converter
If it is not possible to evaluate the HART signal, with a "HART Loop
Converters" up to 3 signals from HART can be converted to 4-20
mA.
The following table lists an approved device:
Type
EC-Type Examination Certificate
Manufacturer
KFD2-HLC-Ex1.D BASEEFA 07 ATEX 0174
Pepperl&Fuchs