Page 74
Version 1.14 (2019-05)
ID-No. 9230-070-en
9.1.3
Can SAFERUN
®
CMS-S
Type
CMS-S
Type of protection:
category 2G
(gas)
Category 2D (dust)
II 2 G Ex ib IIC T1...T6
II 2 D Ex ibD 21 T**
** Temperature class and maximum surface temperature as a function of? Maximum
medium temperature at the installation site and the ambient temperature
temperature
class
Maximum
Surface
temperature
(T**)
ambient temperature
Maximum
Medium temperature
at the installation
T6
80 °C
- 20 °C < Ta < +40 °C
75 °C
T5
95 °C
90 °C
T4
130 °C
125 °C
T3, T2, T1
185 °C
180 °C