GTR058 Installation Manual:
Rev 22
27
The GTR058 can be used as a Push-To-Open gate, you will need to use an Optional
Push-To-Open Bracket (GTR059, sold separately) or mount the Post Bracket
Assembly to the nearest side of the gate post opening. Note that in this configuration,
the gate arm is retracted in the Closed position, and extended in the Open position.
Refer to Figures 22 and 24 for details on how to mount.
To enable Push-To-Open, you will need to change the wires from each
actuator(arm) so that the wire colours match the diagram in Figure 23 below.
Wiring for Push to Open Installation:
Fig 23
Fig 22
Please Note:
Each swing arm contains an internal thread that
may separate if overextended. If overextended a “Click” may
be heard, to re-connect push and screw the arm Clockwise until
the arm begins to retract by hand.
Please Note:
To operate the
gate as push to open the wires
inside the control box for each
motor need to be changed to
match this diagram (right)
Gate in the Closed Position
Gate in the Open Position
2.5cm (1") minimum
2.5cm (1") minimum
Pinch
Area
Pinch Area
Optional Installation: Operating the Gate as Push to Open:
GTR059
bracket required
for push to open installation
(sold separately)