GTR058 Installation Manual:
Rev 22
22
P9: Enable Infrared Photocell Setting.
Enable this setting when Infrared Photocells are being used.
00 – Infrared Photocell disabled.
11 – Infrared Photocell enabled.
Default setting is ‘00’. (infrared photocell disabled)
Note: if you have fitted an infrared photocell for safety such as our GTR208 adjust this
setting to “11” (infrared photocell enabled) to use this safety feature.
PA: Auto Close Setting.
This setting allows you to enable and/or adjust the amount of time a gate stays open before automatically
closing. The value can be set between 1 – 99 seconds. ‘00’ means that the Auto Close feature is disabled
and the gate will stay open until the remote button is pressed again. ‘1’ means the gate will start to close 1
second after it has finished opening.
Default setting is ‘60’ seconds / Gate will automatically close after 60 seconds.
Note: We recommend when using the Auto Close Function that you fit an Infrared safety Photocell such as
our GTR208 to reduce the risk your gate may accidently close on a vehicle or pedestrian.
Pb: Soft Start Setting.
The Soft Start feature means that the gate will start to open slowly for a set period of time, then open at the
regular speed. This can prevent wear and tear on the Gate Opener and the gate itself.
The value can be set between 1 – 9 seconds. ‘1’ means that the Gate Arm will open slowly for 1 second then
proceed at the regular speed.
Default setting is ‘3’.
PC: Soft Stop Setting.
As above, the Soft Stop feature means the gate will slow down slightly before reaching the final closed
position.
Default setting is ’15’.
Note: lowering this program number increases the amount of time the gate will move slowly while closing,
increasing this program number will decrease the total amount of time the gate requires to close.
Pd: Reset to Default Settings
While on the
Pd
setting, press and hold the
‘INC’
or
‘DEC’
button, and the digital display will show
‘dF’
. All
settings will be restored to the default settings.
The digital display will show the status of both Gate Arms during operation. The first symbol refers to Motor 1,
and the second symbol refers to Motor 2. During opening, the symbol will display ‘n’, and during closing the
symbol will display ‘u’.