GTR058 Installation Manual:
Rev 22
20
Programming the Gate Opener:
The following steps detail how to adjust the operation of your swing gate motor, to accommodate individual
operational requirements. While the control box power is turned on, the digital display on the circuit board
will flash
“-- --”
. This means the unit is in operation mode (ready to open and close your gate).
To enter programming mode and change any
program settings press and hold the FUNC
(function button for 4 seconds. The digital
display will flash P1 (Program 1) Meaning
you can adjust Program 1 settings.
• To change settings to any of the programs
press the
INC
(Increase) or
DEC
(Decrease)
buttons, to change the setting option.
Pressing the FUNC button will save the
new setting highlighted and cycle to the
next program option.
•
To exit programming mode and return to
operating mode press the FUNC button
repeatedly until the "-- --" symbol s displayed.
P1: Dual Gate or Single Gate Setting.
11 - Dual Gate Mode (2 swing gate motors fitted)
01 - Single Gate Mode (Single swing gate motor fitted to motor 1 plug)
10 - Single Gate Mode (single swing gate motor fitted to motor 2 plug)
Dual Gate Arm Mode Default setting is ‘11’ (Dual gate mode).
P2: Primary/Secondary Motor Selection Setting.
The Primary Gate is the gate you want to open and close first.
Where possible the motor marked as 'Motor 1' is recommended to be the primary gate.
01 – Motor 1 is the Primary, Motor 2 is the Secondary
10 – Motor 2 is the Primary, Motor 1 is the Secondary
Default setting is ‘01’.
P3: Primary/Secondary Motor Opening Interval Setting.
Adjusting this value will change the time interval between the Primary Gate opening and the Secondary
Gate opening. By default, the Primary gate will begin opening 3 seconds before the secondary gate. If
you would like both your gates to open simultaneously adjust this setting to 0 (seconds).
Default setting is ‘3’.
This value can be set between 0-9 seconds. Setting the value to ‘0’ means both gates will open
simultaneously, while setting the value to ‘9’ means that the Secondary Gate starts to open 9 seconds
after the Primary Gate.
Note: If you are fitting an electric lock to your swing gate. Please keep P3 set to 3 seconds or longer.