GTR058 Installation Manual:
Rev 22
8
Gate Arm Installation:
Before you start:
The G
TR058 Swing Gate Automation Kits are suitable for gates up to 400kg per arm not exceeding 5m in length. Refer
to Table 1 (page 6) to verify that your gate will be suitable. The motor arm uses a worm gear actuator to move your gate.
The swing gate openers must be installed on the inside of the property.
The control box comes with a 1.5m 10 amp 3 pin power cable. This should be plugged into an appropriate weatherproof
power outlet, which must be installed by a qualified electrician. Do not extend the power cable. Make sure the power
cord is protected from flooding, tripping and any other damage. If in any doubt, we recommend shielding all cables with
electrical conduit.
Please Note: This gate kit is FACTORY set to be a PULL to OPEN.
If you require a PUSH to OPEN setting please refer to Page 27 for PUSH to OPEN instructions
Inside
Outside
Inside
Outside
Is the gate being installed as Pull to Open or Push to Open?
Pull to Open
Default Setting
Gate opens inwards towards the property
Refer to page 11 for pull to open instructions
Refer to page 27 for push to open instructions
Please note: your gate must never open into public spaces
Push to Open
Optional Setting
Gate opens outwards from the property