~DESCRIPTIONS OF FUNCTION CODE SETTINGS~
- 35 -
D.
F_003
: Selection of validity of STOP on keypad
a.
F_003
= 0
Indicate terminals generate start signal and STOP on keypad is
invalid.
b.
F_003
= 1
Indicate terminals generate start signal and STOP on keypad is
valid.
E.
F_004
: Select function of changing frequency for KP-201C
a.
F_004
= 0
Indicate KP-201C is in monitor mode and the frequency setting
can not be changed.
b.
F_004
= 1
Indicate KP-201 is in monitor mode and the frequency setting
can be changed.
F.
F_005
: Select function of storing frequency for KP-201C
a.
F_005
= 0
Indicate KP-201C is in monitor mode, the main speed setting
value can not be stored automatically.
b.
F_005
= 1
Indicate KP-201C is in monitor mode, the main speed setting
value can be stored automatically after 3 minutes later.
G.
F_006
: Select main display of KP-201C
This function is designed for KP-201C. In the monitor mode, there
are 8 displays as followings.
1. Output frequency 5. Output current
2. Frequency setting
6. Motor speed (RPM)
3. Output voltage 7. Line velocity (MPM)
4. PN voltage 8. Status of terminals
Indicate terminals generate start signal and STOP on keypad is
valid.
c.The usage of "STOP" key
(I) When "STOP" key use as urgent stop like following:
When Inverter start and running control by input terminal
(F_001=0 or1), it needs to push "STOP" key during Inverter
working, then output frequency will down to 0.00HZ, the
KP-201C will show "000". The usage of restart action is, to
release the FWD or REV terminal between COM first, then
to do restart action.
(II) "STOP" key use as common stop:
When F_001=2 or 3, the start action is control by KP-201C
"RUN" Key, then stop action is control by KP-201C "STOP"
key.