LIST OF FUNCTION CODE SETTING~
- 31 -
Function
Name
Descriptions
Range of
setting
Resolu-
tion
Factory
setting
No. page
reference
for detail
F_105
Deceleration time
2 of power source
for shutdown
Deceleration time when output frequency
smaller than switch frequency (F_106)
0.0~3200.0
0.1S
15.0
(Re.5)
63
F_106
Switch frequency of
power source for
shutdown
Frequency setting value of switch the
deceleration time of speed level 2.
0.0~400.0
0.1HZ 0.0 63
F_107
ADJ1 parameter
setting
ADJ1 of KP-202C function is boost voltage , it
can’t be changed
—
—
0
69
F_108
ADJ2 parameter
setting
ADJ2 of KP-202C function is primary acc.
time , it can’t be changed.
—
—
0
69
F_109
ADJ3 parameter
setting
ADJ3 of KP-202C function is primary dec.
time , it can’t be changed
—
—
0
69
F_110
Selection of
parameter of ADJ4
Selecting parameter of ADJ4 of KP-202C
0~49
—
1
69
F_111
Selection of
parameter of ADJ5
Selecting parameter of ADJ5 of KP-202C
0~49
—
20
69
F_112
Selection of
parameter of ADJ6
Selecting parameter of ADJ6 of KP-202C
0~49
—
17
69
F_113
Selection of
parameter of DIP1
Selecting parameter of DIP1 of KP-202C
0~15
—
8
69
F_114
Selection of
parameter of DIP2
Selecting parameter of DIP2 of KP-202C
0~15
—
5
69
F_115
Selection of
parameter of DIP3
Selecting parameter of DIP3 of KP-202C
0~15
—
3
69
F_116
Selection of
parameter of DIP4
Selecting parameter of DIP4 of KP-202C
0~15
—
1
69
F_117
Setting
potentiometer
of KP-202C
Selecting parameter of setting potentiometer of
KP-202C
0~49
—
0
69
F_118
Selection of
UP/DOWN
memory control
0:Clear UP/DOWN frequency for shutdown power
1:Store UP/DOWN frequency for shutdown power
0,1
—
0
51
F_119
UP/DOWN adjust
frequency
0: 0.01Hz , 1~8:*0.05Hz , 9:0.5Hz ,
10~250:*0.1Hz
0
∼
250
—
0
51
F_120
UP/DOWN
adjust Time
1~5:
Terminal adjust response time, continuous
acceleration (deceleration) when over setting time
6
:Edge trigger
1~6
—
1
51
F_121
UP/DOWN
frequency adjust
Adjust UP/DOWN frequency from KEYPAD directly
0.00~400.00
0.01HZ
0.00 52
F_122
Selection of
secondary
speed
0:Indicate the frequency is set by terminals
1:Indicate the frequency is set by keypad
2:Indicate the frequency is set by UP/DOWN
terminals
0~2
—
0
53
F_123
Select source of
analog input
0: Vin+Iin 1:Vin – Iin 2:Iin-Vin
3:
Vin or Iin (switch by multi-function input terminal)
0~ 3
—
0
44
F_124
Selection of
Vin analog
input
0: Analog input gain 1: Frequency command
2: Current limit level
3: Output voltage adjustment of V/F pattern
0~ 3
—
1
44
F_125
Selection of Iin
analog input
0: Analog input gain 1: Frequency command
2: Current limit level
3: Output voltage adjustment of V/F pattern
0~ 3
—
1
44
F_126
Selection of
Iin analog
input range
0: 4~20mA (2~10V) 1: 0~20 mA (0~10V)
0,1
—
0
44
F_127
Iin frequency
command gain
Proportional gain between Iin analog frequency
command and output frequency
0.00~2.00
0.01 1.00 43
F_128
Iin frequency
command bias
Gain of Iin analog bias frequency
-1.00~1.00
0.01 0.00 43
The color as