~DESCRIPTIONS OF FUNCTION CODE SETTINGS~
- 41 -
Base frequency /40
V/F voltage
limited pattern
Output frequency
Output voltage
250V
20V
10V
Base frequency
(F_034)
(4) V/F pattern settings
A.
F_030
: Limitation of output voltage
a.
F_030
= 0
Output voltage is not limited
b.
F_030
= 1
Output voltage is limited and can not be greater than the limited
voltage of V/F pattern. (200V class max. limited voltage=
250.0V, 400V class max. limited voltage= 500.0V)
B.
.
F_031
: Max. output frequency
RM5G series: Max. output frequency range 0.1~ 400.0Hz
RM5P series: Max. output frequency range 0.1~ 120.0Hz
C.
F_032
:
Start frequency with range 0.1~10.0 Hz.
D.
F_033
:
Boost voltage. (Range 0.1~50.0 V for 200V class, and
0.1~100.0 V for 400V class)
E.
F_034
:
Base frequency with range 0.1~400.0 Hz
F.
F_035
:
Base voltage. (Range 0.1~255.0 V for 200V class, and
0.1~510.0 V for 400V class)
G.
F_036
:
Frequency at the changing point 1 with range 0.0~399.9
Hz
H.
F_037
:
Voltage at the changing point 1. (Range 0.0~255.0 V for
200V class, and 0.0~510.0 V for 400V class)
I.
F_038
:
Frequency at the changing point 2 with range 0.0~399.9
Hz
J.
F_039
:
Voltage at the changing point 2. (Range 0.0~255.0 V for
200V class, and 0.0~510.0 V for 400V class
)