~DESCRIPTIONS OF FUNCTION CODE SETTINGS~
- 40 -
Freqency
setting
Time
S-curve acc./dec. time chart
S curve time
Output
Frequency
Max. Output
freqency
(F_031)
Time
Secondary acc./dec. and the inhibition
command for acc. and dec. chart
Secondary acc./dec.time
(Multiple function input terminals)
F_019
F_027
F_028
F_020
Primary
acc. time
Secondary
acc. time
Secondary
dec. time
Primary
dec. time
Inhibition command for acc./dec.time
(Multiple function input terminals)
d.
If the stop signal is generated, the command of inhibiting
acc./dec. is useless.
Note: that there are 4 types of STOP signal described as followings:
(1) If F_001=0 or 2, FWD and REV are either open or close
simultaneously.
(2) If F_001=1, FWD is open.
(3) If F_003=1, press STOP.
(
4
) If start command is generated by keypad, press STOP.
e.
The acceleration/deceleration times of S curve acceleration/
deceleration are set for smooth running, for example, to avoid
the drop of object in transmission line or shock of elevator.