LIST OF FUNCTION CODE SETTING~
- 30 -
Function
Name
Descriptions
Range of
setting
Resolu-
tion
Factory
setting
No. page
reference
for detail
F_082 Types of stop
0: Indicate stop by deceleration
1: Indicate stop by free running
0,1
—
0
67
0: Indicate that reversal rotation is allowed
F_083
Inhibition of
reversal rotation 1: Indicate that reversal rotation is not allowed
0,1
—
0
67
F_084 Jumping
frequency 1
To avoid the resonance of machinery, the jump of
frequency command is occurred in frequency 1
0.0~400.0 0.1Hz
0.0 64
F_085 Jumping
frequency 2
To avoid the resonance of machinery, the jump of
frequency command is occurred in frequency 2
0.0~400.0 0.1Hz
0.0 64
F_086 Jumping
frequency 3
To avoid the resonance of machinery, the jump of
frequency command is occurred in frequency 3
0.0~400.0 0.1Hz
0.0 64
F_087
Jump of
frequency
The setting of the jump of frequency command
in frequency 1,2,3
0.0~25.5 0.1Hz
0.0 64
F_088
Current for
speed tracking
If the current is larger than speed tracking, the
output frequency is decreased
0~200%
by the inverter
rated current
1%
150 65
F_089
Time interval for
speed tracking
The time interval, with zero output frequency,
preceding with speed tracking
0.5~5.0
0.1S
0.5 65
F_090
V/F pattern of
speed tracking
In the speed tracking, the setting of percentage of
output voltage obtained from the original V/F pattern.
0~100%
1%
100 65
F_091
Fault records
Display the last 5 records of faults.
—
—
no_Err
67
F_092 Lock of
parameters
0: Parameters are changeable. Max. frequency
can not over 120.0Hz.
1: Parameters are locked. Max. frequency can
not over 120.0Hz.
2: Parameters are changeable. Max. frequency
can over 120.0Hz.
3: Parameters are locked. Max. frequency can
over 120.0Hz.
0~3
—
0
67
0: Indicate that voltage is not regulated
automatically .(Re.7)
F_093
Selection of
automatic voltage
regulation
1: Indicate that voltage is regulated
automatically.
0,1
—
1
67
0: Indicate that there is no overload protection.
F_094
Selection of the
overload protection
of inverter (OLI)
1: Indicate that there is overload protection.
0,1
—
1
68
190.0~
240.0
220.0
(Re.3)
F_095
Voltage level of
power source
The range of setting is in accordance with
power source.
340.0~
480.0
0.1V 380.0
(Re.4)
68
F_096
Creeping
Frequency setting
The output frequency is accelerated to creeping
frequency and then is in constant frequency.
0.0~400.0 0.1Hz
0.5 65
F_097
Time duration
of creep
The time interval for output frequency to be
accelerated to creeping frequency.
0.0~25.5
0.1S
0.0 65
F_098 Reserved
Reserved
—
—
0
66
F_099
Selection of display
of external
indicator 1
Selection of display of external indicator 1
0 ~ 8
—
1
(Re.8) 66
F_100
Selection of display
of external
indicator 2
Selection of display of external indicator 2
0 ~ 8
—
2
(Re.8) 66
F_101
Selection of display
of external
indicator 3
Selection of display of external indicator 3
0 ~ 8
—
3
(Re.8) 66
F_ 102
Selection of energy
saving device
0: Do not equip energy-saving device.
1: Equip energy-saving device.
0,1
—
0
68
F_ 103
Decrease frequency
of deceleration time
of shutdown power
source
If power source shutdown, then the
Frequency = output frequency - decrease
frequency.
0.0~20.0 0.1Hz
3.0 63
F_ 104
Deceleration time 1
of power source for
shutdown
Deceleration time when output frequency larger
than switch frequency (F_106)
0.0~3200.0 0.1S
15.0
(Re.5) 63
The color as