![Renesas IDT Tsi574 User Manual Download Page 377](http://html1.mh-extra.com/html/renesas/idt-tsi574/idt-tsi574_user-manual_1440935377.webp)
12. Serial RapidIO Registers > Utility Unit Registers
377
Tsi574 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
12.12
Utility Unit Registers
The utility block contains global registers for interrupts and clocking.
12.12.1
Global Interrupt Status Register
This register indicates which block within the Tsi574 has generated an interrupt. The interrupt requests
from a given block are “ORed” together and the value of the output is reflected in this register.
Register name: GLOB_INT_STATUS
Reset value: 0x0000_0000
Register offset: 1AC00
Bits
0
1
2
3
4
5
6
7
00:07
Reserved
RCS
MCS
I2C
TEA
08:15
Reserved
MC_LAT Reserved
16:23
Reserved
24:31
PORT7
PORT6
PORT5
PORT4
PORT3
PORT2
PORT1
PORT0
Bits
Name
Description
Type
Reset
Value
0:3
Reserved
N/A
Note: These upper 4 bits are reserved in order to be compatible with the
I2C Interface
R
0
4
RCS
Combined four Reset Control Symbols interrupt status from all ports
R
0
5
MCS
Combined Multicast-Event Control Symbol interrupt status from all ports
R
0
6
I2C
I2C Interrupt Port
R
0
7
TEA
TEA occurred in fabric. To determine what port(s) experienced the TEA,
see
“Fabric Interrupt Status Register” on page 374)
.
R
0
8:13
Reserved
N/A
R
0
14
MC_LAT
At least one broadcast buffer has exceeded its maximum multicast
latency timeout. To find out which ports have experienced this error,
refer to
“RapidIO Broadcast Buffer Maximum Latency Expired Error
.
R
0
15:23
Reserved
N/A
R
0
24
PORT7
Port 7 Interrupt
R
0
25
PORT6
Port 6 Interrupt
R
0
26
PORT5
Port 5 Interrupt
R
0