Manual - TC.P Quadro
1) Internal (PDSP)
2016-08-05
270/330
V04.52
9
9.1.2.
1) Internal (PDSP)
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
2-1
10
PDSP pack-age
check-sum
System communication failed.
A strong EMI pulse.
Extensive measures to thor-oughly earth the de-
vice is needed.
Find the EMI sources e.g. contactors without free
wheeling diodes.
2-2
11
Wrong PDSP SW
version
The version of the peripheral DSP
does not support the version of the
main DSP.
The peripheral DSP wasn’t suc-
cessfully refreshed during a soft-
ware update.
Newest parameters aren’t loaded
after a software update.
You have to follow the Soft-ware update instruc-
tions in the manual.
2-3
12
PDSP fault
An internal error occurred.
In the case of repeated occur-
rence refer to customer support.
no
2-4
13
Write queue over-
run
An internal error occurred.
In the case of repeated occur-
rence refer to customer support.
no
2-5
14
Too many PDSP
packages
An internal error occurred.
In the case of repeated occur-
rence refer to customer support.
no
2-6
15
SCI check-sum
Various errors on interface RS232.
Interference on the RS232 cable.
Extensive measures to thor-oughly earth the de-
vice is needed.
Use a shorter cable.
Use a shielded cable.
Prevent ground loops. Use a voltaic isolated
RS232 interface.
Find the EMI sources
e.g. contactors without free wheeling diodes.
2-7
16
SCI parity
Various errors on interface RS232.
Wrong RS232 timings are set
(baud rate, stop bit, parity bit, ...).
Correct the settings according to the device man-
ual.
2-8
17
SCI overrun
Various errors on interface RS232.
Wrong RS232 timings are set
(baud rate, stop bit, parity bit, ...).
Correct the settings according to the device man-
ual.
2-9
18
SCI framing
Various errors on interface RS232.
Level switching on RS232 Inter-
face while PC/Laptop is switched
on/off .
Plug in the RS232 cable after booting PC/laptop
and re-move it before shut-down.
Update the peripherals DSP to at least version
0.11.