Manual - TC.P Quadro
5) Temperature
2016-08-05
280/330
V04.52
9
9.1.6.
5) Temperature
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
6-1
50
Rectifier temp. too
high
Heat sink temperature near output
rectifier too high.
Insufficient supply and exhaust air
flow of cooling air.
Ambient temperature too high.
Load current too high (tempera-
ture rises).
Replace clogged filter. Allow supply and exhaust
air sufficiently flow without limitation.
Reduce ambient temperature to allowed range.
Adapt load to ambient temperature (Notice the
temperature derating).
6-2
51
IGBT temp. too
high
Heat sink temperature near IGBT
power stage too high.
Insufficient supply and exhaust air
flow of cooling air.
Ambient temperature too high.
Load current too high (tempera-
ture rises).
Replace clogged filter. Allow supply and exhaust
air sufficiently flow without limitation.
Reduce ambient temperature to allowed range.
Adapt load to ambient temperature (Notice the
temperature derating).
6-3
52
TC.LIN K1 temp.
too high
Heat sink temperature of TC.LIN
output stage too high.
Supply and exhaust air flow of
cooling air is restricted or the am-
bient temperature is too high.
Cf. 50) and 51)
6-4
53
TC.LIN K2 temp.
too high
Heat sink temperature of TC.LIN
output stage too high.
Supply and exhaust air flow of
cooling air is restricted or the am-
bient temperature is too high.
Cf. 50) and 51)
6-5
54
TC.LIN PCB temp.
too high
Temperature of TC.LIN PCB too
high.
Supply and exhaust air flow of
cooling air is restricted or the am-
bient temperature is too high.
Cf. 50) and 51)
6-6
55
Case Inside
temp.high
Temperature inside of TopCon hous-
ing exceeds the limitsTemperature of
environment (e.g. of cabinet) too
high
Temperature of environment (e.g.
of cabinet) too high
Increase air circulation, provide cold air intake.
Cf. 50) and 51)
6-7
56
TC.LIN K1 cable
break
TC.LIN Temperature Sensor K1
gives no signal
Cable break or sensor not con-
nected
Contact customer support
6-8
57
TC.LIN K2 cable
break
TC.LIN Temperature Sensor K2
gives no signal
Cable break or sensor not con-
nected
Contact customer support
6-9
58
TC.LIN PCB cable
break
TC.LIN Temperature Sensor on PCB
gives no signal
Sensor not mounted
Contact customer support
6-10
59
Transformer temp.
high
Transformer temperature exceeds
the limit.
Load current too high (Notice the
temperature derating).
Adapt load to ambient temperature (derating).