Manual - TC.P Quadro
TopControl application
2016-08-05
227/330
V04.52
6
Multi-module system configuration dialog box
The following conditions must be met for multi-unit system operation:
Entries are made on the master device in the multi-unit system.
The master-slave principle on all devices involved in the multi-
unit system see chapter 5.3.3.1, page 136.
2
1
7
4
3
5
6
Fig. 135
The “Multi-module system configuration” dialog box is opened via
the
<CONFIG>
-1-
tab by clicking the
<System Configuration...>
button.
Multi-module system configuration - parameters
3
<System>,
list box
Single Device
Device on its own.
Hidden:
-4-,
-5-
Multi-Load
Although devices are remotely controlled from the master
device and they are connected via CAN, their power outputs
are not connected together.
Each slave device has its own load. Identical set values are
specified for each device.
Visible
-4-
Matrix
See Table 137, page 228.
4
<Number of devices in-line>
1
,
numeric box
Number of device in a multi-unit system that are connected in series.
5
<Number of parallel lines>
1
,
numeric box
Number of device in a multi-unit system that are connected in parallel.
6
<Enable>
2
, check box for TC.LIN
7
<Current Range>
2
, list box for TC.LIN