Manual - TC.P Quadro
3) Output voltage
2016-08-05
275/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
4-7
36
Output undervolta-
ge
The voltage fall below the set level
for a predefined duration.
Controller undershooting
Decrease controller parameters - possibly increas-
ing the proportional part (P Gain).
4-7
36
Output undervolta-
ge
The voltage fall below the set level
for a predefined duration.
Undershooting caused by set val-
ue steps.
Reduce the gradient of the set value ramp.
Reduce controller parameters.
4-7
36
Output undervolta-
ge
The voltage fall below the set level
for a predefined duration.
The given reference value is too
low.
Increase reference value.
4-8
37
Overvoltage DC
Discharge Unit
Voltage on DC Discharge Unit ex-
ceeds specified limit
The connected load violate the
specified limits.
Check if the connected load does not violate the
specified limits.