Manual - TC.P Quadro
Commissioning
2016-08-05
66/330
V04.52
3
9
1
2
3
2
1
2
7
17
Fig. 30
Explanation of function of interlock circuit for single device.
Connection of the interlock circuit
1
Dummy plug X101
Safety circuit is closed using a jumper.
Terminating resistor for the CAN bus
2
External EMERGENCY STOP button
3
Dummy plug X105
Safety circuit is closed using a jumper.
Table 41
Connection of the interlock circuit.
Interfaces used for the interlock safety circuit
X101/X102
Suitable for external
EMERGENCY STOP button
.
In multi-unit systems
the interlock circuit is interrupted immedi-
ately on the operation of an EMERGENCY STOP. All devices in
the multi-unit system are shut down simultaneously.
X105
Suitable for an external
EMERGENCY STOP button on a sin-
gle device
. The interlock contact is interrupted on the local sin-
gle device.
In the multi-unit system the shutdown signal is only passed on
via the internal device communication with a delay.
To be able to place a TopCon power supply in operation, these inter-
faces must be connected appropriately.
Use dummy plugs supplied!
In the simplest configuration corresponding dummy plugs must be fitted
to the two interfaces X101 and X105.
For information on dummy plugs see chapter 3.2.4.6, page 62.