Manual - TC.P Quadro
Commissioning
2016-08-05
47/330
V04.52
3
Cooling
TopCon power supplies are equipped with forced air cooling in the
standard version. For this reason the supply of cooling air is to be en-
sured while complying the maximum permissible temperature and
humidity (see chapter 3.1.6, page 38).
1
2
2
3
2
4
4
Fig. 16
Scheme of the passage of the air on installation in a cabinet case.
1
Air supply
2
Air exhaust
,
3
Depth to the rear wall
, 150 mm
4
Air short-circuit,
must be prevented
Table 32 Schematic illustration of the cooling air flow.
For the supply and removal of cooling air, sufficiently large, suitable
cases with corresponding inlet and outlet openings for the passage of
the cooling air are to be used.