Manual - TC.P Quadro
R) Miscellaneous 2
2016-08-05
319/330
V04.52
9
Flash
Code
Error
Error message
TopCon (Long)
Description
Possible Cause
Counteraction
26-8
R7
DC Discharge Unit
not ready (wait time
not up for cooling
down)
Voltage On is not allowed.
The DC Discharge Unit is not
cooled down sufficiently.
Wait until the DC Discharge Unit has cooled down
sufficiently.
26-9
R8
High Dynamic
Lookup Table miss-
ing for S3R mode
For S3R Mode a High Dynamic
Lookup Table is needed
Device is configured for S3R
mode but no High Dynamic
Lookup Table is available
Contact customer support
26-10 R9
Error on deleting all
function generator
curves at power-up
The automatic deletition of all func-
tion generator curves at power-up is
enabled but could not be executed
correctly.
Timing error or defect flash sector.
Contact customer support if the error keeps occur-
ring