Manual - TC.P Quadro
TopControl application
2016-08-05
231/330
V04.52
6
6.4.7.7. Tab
– <ADJUST 1>
User level: from Power User
Any adjustments on the measured value acquisition on the inputs and
outputs necessary during the test and setup phase for the TopCon
power supply can be made using the parameters on the <ADJUST 1>
tab.
For further information on analogue remote programming, see chapter
3.3.3.4, page 75.
Damage possible due to decalibration!
Changes to the parameters can cause damage to the load connected:
The control circuit may overshoot, which will involve current
and voltage spikes that can irreparably damage the semicon-
ductors.
Damage to a load connected due to excessively high voltage,
current or power steps.
Avoidance:
Please contact Regatron support first if you are uncertain.
Check changes to parameters for safety, prior to saving on
the TopCon power supply.
In the TopControl application the analogue input signals on interface
X105 are allocated the following numerical values as set values that are
displayed on the tab:
Input/output signal -10 V
≙
-4000 numerical value
Input/output signal 0 V
≙
0 numerical value
Input/output signal 10 V
≙
4000 numerical value
In the case of recalibration, please contact Regatron support.
CAUTION