SPECIFICATIONS
Batteries:
CAM-10 Use 2 LR44 button cell batteries
Operating Range:
50-600 VAC, 50-60 Hz
Voltage Indicators:
Audible & Visual Alert
Operating Temperature:
32-122°F (0-50°C)
Storage Temperature:
0°F (-18°C) to 156°F (70°C)
Humidity:
80% RH maximum below 86˚F(30˚C),
50% RH maximum above 86°F (30°C)
Altitude:
Up to 6561 feet (2000 meters)
Safety:
For indoor use and in accordance with over
voltage category III, Pollution degree 2
Intended Use:
Non-contact AC voltage detection
Serial No:
See interior of battery cover
CLEANING
Use clean, dry cloth. Do not use any type of solvent.
BEFORE USE
READ ALL OPERATING INSTRUCTIONS BEFORE USE. FOR
INTENDED USE ONLY.
Protection provided by this product
may be impaired if used with accessories not provided by the
manufacture or if used as in a manner other than specified within.
WARNING:
To be used by trained person only. High voltage AC
and DC circuits are dangerous. Use extreme caution and use as
intended when testing potentially live circuits. Risk of Electrocution.
WARNING:
This product should be used to test or detect
insulated wires and terminals but should not be used to
contact Live Circuits. This tester will not detect voltage in wires
that are electrically shielded by metal conduit or grounded
enclosures. Risk of Electrocution.
OPERATION
Before use, test the batteries of the CAM-10 tester by pressing
the button on the tester marked PRESS. A momentary audible
tone and flash of the light are an indication that the unit is working.
WARNING:
Always test on known live circuit before use.
To test for voltage:
1. Hold the screwdriver with your thumb on the
CAM-10 tester button marked PRESS,
keeping hands and fingers well away
from the sensor (red end).
2. Press down and hold the test button
on the tester. A momentary alert
indicates the unit is working.
3. Place the sensor (red end) near
the wire or device to be tested.
Maintain a minimum distance of
0.5mm from contacting the wire
or device to be tested. If voltage
greater than 50 VAC is present, the tester
light and tone will activate rhythmically at
10 to 15 cycles second.
To detach the tester
from the screwdriver, apply force to the
tester near the Gardner Bender logo and slide the tester from
the holding slot. The tester can be used to test for voltage after
it is detached per instructions within. Hold the tester as shown,
keeping hands and fingers well away from the sensor (red end).
CAM-10 BATTERY REPLACEMENT
Remove the Phillips
®
head screw from the bottom of the CAM-10
tester. Lift off the battery cover from the top of the tester. Insert
2 LR44 batteries in the orientation indicated on the side of the
battery cover. Replace cover and screw.
ESPECIFICACIONES
Baterías:
El modelo CAM-10 usa 2 baterías de botón LR44
Rango operativo:
50-600 VCA, 50-60 Hz
Indicadores de voltaje:
Alerta sonora y visual
Temperatura operativa:
0-50°C
Humedad:
80% HR máxima, 50% HR máxima sobre 30°C
Altitud:
Hasta 2000 metros
Seguridad:
Para uso en interiores y conforme a la categoría III
de sobrevoltaje
Grado de contaminación 2. IEC 529, IEC 1010
Uso previsto:
Detección de voltaje CA sin contacto
LIMPIEZA
Use un paño limpio y seco. No use ningún tipo de solvente.
ANTES DEL USO
LEA TODAS LAS INSTRUCCIONES OPERATIVAS ANTES DEL
USO. SÓLO PARA EL USO PREVISTO.
ADVERTENCIA:
Son peligrosos los circuitos de CA y CC de
alto voltaje. Tenga sumo cuidado y utilice de la manera prevista
al probar circuitos potencialmente energizados. Riesgo de
electrocución.
ADVERTENCIA:
Este probador no detecta el voltaje en cables
que tienen blindaje eléctrico mediante portacables de metal o
cierres puestos a tierra. Riesgo de electrocución.
OPERACIÓN
Antes de usar, pruebe las baterías del probador
CAM-10 oprimiendo el botón en el probador que está marcado
PRESS. Un tono audible momentáneo y un destello de luz son
indicaciones de que la unidad está funcionando.
ADVERTENCIA:
Siempre pruebe en un circuito
energizado conocido antes de usar.
Para probar el voltaje:
1. Sostenga el destornillador con el pulgar
en el botón del probador CAM-10
marcado PRESS, manteniendo las
manos y los dedos bien alejados
del sensor (extremo rojo).
2. Oprima y mantenga así el botón
de prueba en el probador.
Limited Lifetime Warranty limited solely to repair or replacement; no warranty or
merchantability or fitness for a particular purpose. Product is warrantied to be free
of defects in materials and workmanship for the normal life of the product. In no
event shall Gardner Bender be liable for incidental or consequential damage.
GB
SDT-3, SDT-6, SDT-10
Screwdrivers
CAM-10
Non-contact Voltage Tester
OPERATING
INSTRUCTIONS
Patents Pending
SDT-3, SDT-6, SDT-10
Destornilladores
CAM-10
Probador de voltaje sin contacto
INSTRUCCIONES
OPERATIVAS
Patentes pendientes
GB
SYMBOLS
This equipment has double insulation with respect to live circuits
Attention, consult the accompanying documents
!
!