Setting instructions for the product sensor type 1
No.
View / Functional element
Description / Step
1
Display element
Operating display
–green– (1)
The green LED indicates the operating mode of the
sensor. Continuous green light indicates that the
sensor is in operating mode and is working in a stable
range. If the green LED is off when the orange LED is
on, the setting has to be corrected. The sensor is
working in an insecure / non-stable range.
Output display
–orange– (2)
This orange LED indicates the status of the sensor. If
the display is lit, the output is active (supply voltage is
on at the output).
Controls:
Sensitivity setting (3)
The sensitivity (range) of the sensor can be adjusted
with this control. In the position "min" (left stop), the
sensor has the lower degree of sensitivity (range), in
the position "max" (right stop) it has the highest degree
of sensitivity (range). This control has a mechanical
setting range of approx. 280 degrees.
Switch for output function (4)
This control is a rotary switch and not a control. This
switch is used to switch between light switching =
L
(
L
ight) and dark switching =
D
(
D
ark). In the operating
mode
L
, the output of the sensor becomes active if a
product reflects back the (infrared) light sent from the
sensor to the sensor (the sensor responds to incoming
light). In operating mode
D
, the output becomes active
when no (infrared) light falls onto the sensor.
Operating mode "L" is used in most applications.
2
Step 1:
Set the sensor to the operating mode "light switching"
=
L
. Please set the rotary switch to left stop (counter
clockwise), but do not overwind the controls!
In this operating mode, the output signal is generated
high-level if the light club of the sensor detects a
product/object.
3
Step 2:
Please ensure that there are no products or other
objects in the input area.
1
2
3
4