Instruction manual
Page 128 / 189
Copyright © REA Elektronik
REA JET HR
pro
2K / 4K
V 3.5x_001 28.05.2015
4.2.18.3.2
Electrical limit values of the product sensor connection
Name / Function
Value
Unit
Tolerance
V
out
Output voltage of the HR to supply
the sensor
24
V DC
+/- 15 %
I
out
Max. load of output voltage of the HR
to supply the sensor
150
mA
V
in L
Input voltage "Low
– Pegel"
< 4
V DC
very
sensitive
V
in H
Input voltage "High
– Pegel"
> 11
V DC
I
in max.
Max. input current (load current) for
the sensor
2
mA
t
min
min. signal power-on time
1
µs
Table 28: Electrical limit values of the product sensor connection
4.2.18.3.3
Functional circuit diagram of the product sensor connection
Circuit diagram 5: Functional circuit diagram of the product sensor connection on the print header
4.2.18.3.4
Delivery scope and measurements of the product sensor plug
connector
Figure 175: Scope of delivery of the sensor plug
Figure 176: Dimensions of the sensor plug