Remote control commands
R&S
®
AREG800A
315
User Manual 1179.3615.02 ─ 01
Manual operation:
See
[:SOURce<hw>]:AREGenerator:OBJect<ch>:ATTenuation
<AregObjAtt>
Sets the attenuation of the radar object.
Parameters:
<AregObjAtt>
float
Range:
0 to 63.5
Increment: 0.5
*RST:
50
Example:
Example "Configuring static radar objects"
Manual operation:
See
[:SOURce<hw>]:AREGenerator:OBJect<ch>:DOPPler[:SPEed]
<AregObjectDopp>
Sets the Doppler speed of the radar object.
If you do not specify a speed unit, the default unit is used.
Parameters:
<AregObjectDopp>
float
Range:
-500 to 500
Increment: depends on options
*RST:
0
Default unit: km/h
Example:
SOURce1:AREGenerator:UNITs:DOPPler SPEed
SOURce1:AREGenerator:OBJect4:DOPPler 80
// Sets the Doppler speed to 80 km/h.
SOURce1:AREGenerator:OBJect4:DOPPler 80mph
// Sets the Doppler speed to 80 mph (miles per hour).
SOURce1:AREGenerator:OBJect4:DOPPler 80mps
// Sets the Doppler speed to 80 m/s (meters per second).
Example:
Example "Configuring static radar objects"
Manual operation:
See
[:SOURce<hw>]:AREGenerator:OBJect<ch>:DOPPler:FREQuency
<AregObDoppFreq>
Sets the Doppler frequency or Doppler shift of the radar object.
SOURce subsystem