Configuring radar objects
R&S
®
AREG800A
63
User Manual 1179.3615.02 ─ 01
Settings:
Logging Configuration settings
................................................................................63
5.4.1
Logging Configuration settings
Access:
► Select "Radar Objects > Logging > Logging Config".
The "Logging Config" tab provides settings to activate logging and to configure the
scope and the time base of logged data.
State
Activates logging.
You can define the scope of logged data, see
Remote command:
[:SOURce<hw>]:AREGenerator:DLOGging[:STATe]
Logging Level
Defines the scope of logged data.
"All"
Logged data includes information on errors, warnings and info mes-
sages.
"Error and Warning"
Logged data includes information on errors and warnings.
"Error"
Logged data includes information on errors.
Remote command:
[:SOURce<hw>]:AREGenerator:DLOGging:LEVel
Timebase
Sets the time base of the logged data.
Remote command:
[:SOURce<hw>]:AREGenerator:DLOGging:TBASe
Logging settings