Configuring the measurement setup
R&S
®
AREG800A
89
User Manual 1179.3615.02 ─ 01
For information on the I/Q modulation performance in any of the modes, see the data
sheet.
"Fast"
Fast optimization by compensation for I/Q skew.
This mode is suitable in time sensitive environments and narrowband
signal.
"High Quality"
Enables an optimization by compensation for I/Q skew and frequency
response correction.
This mode generates flat signal over large bandwidth but requires
longer setting time and leads to signal interruption.
Remote command:
[:SOURce<hw>]:AREGenerator:CHANnel:OPTimization:MODE
IF Frequency
Sets the intermediate frequency of the channel.
Remote command:
[:SOURce<hw>]:AREGenerator:CHANnel:IF
6.5
Channel mapping
Access:
► Select "Measurement Setup > Configuration > Channel Mapping".
The "Channel Mapping" tab of the "Measurement Setup" dialog opens.
The tab provides settings for channel mapping of up to eight radar channels in a table.
Also, it provides settings to adjust channel power levels and it provides access to fur-
ther settings to adjust channel power levels.
Channel mapping