Remote control commands
R&S
®
AREG800A
261
User Manual 1179.3615.02 ─ 01
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
n.a. (factory preset: 1)
Example:
See
Example "Activating screen saver mode and display
Manual operation:
See
:DISPlay:ANNotation:FREQuency
<State>
Indicates asterisks instead of the frequency values in the status bar.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
n.a. (factory preset: 1)
Example:
See
Example "Activating screen saver mode and display
Manual operation:
See
:DISPlay:ANNotation[:ALL]
<State>
Displays asterisks instead of the level and frequency values in the status bar of the
instrument.
We recommend that you use this mode if you operate the instrument in remote control.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
See
Example "Activating screen saver mode and display
:DISPlay:DIALog:ID?
Returns the dialog identifiers of the open dialogs in a string separated by blanks.
Return values:
<DialogIdList>
<DialogID#1>< ><DialogID#2>< > ... < ><DialogID#n>
Dialog identifiers are string without blanks. Blanks are represen-
ted as
$$
.
Dialog identifiers
<DialogID>
are composed of two main parts:
<DialogName>[<OptionalParts>]
<DialogName>
Meaningful information, mandatory input parameter for the com-
mands:
DISPlay subsystem