Evaluation Range...
The "Evaluation Range..." button opens the
that allows you to
restrict the frequency range of auto length (and loss) calculations.
5.13.2.2
Fixture Compensation dialog
This dialog allows you to correct the measurement result for the effects of a test fixture.
Access:
●
Channel – [Offset
Embed] > "Offset" > "Fixture Compensation..."
●
Channel – [Offset
Embed] > "One Way Loss" > "Fixture Compensation..."
Background Information
Refer to
Chapter 4.6.1.5, "Fixture Compensation"
Figure 5-55: Fixture Compensation dialog (for >4 ports)
Ports
Selects the ports for whom fixture compensation data shall be acquired.
Auto Length / Auto Length and Loss
"Auto Length" or "Auto Length and Loss" implies that a global electrical length offset
and loss is determined in analogy to the general offset compensation (see
on page 204 and
Chapter 4.6.1.4, "Auto Length and Loss"
Remote command:
[SENSe:]CORRection:COLLect:FIXTure:LMParameter:LOSS[:STATe]
Offset Embed softtool