4.6 Performance Specifications
4.7 Power
The rack-mount receiver requires 100 to 240 VAC, 50/60 Hz power.
4.8 RF Frequency Error
By default, the RDMS™ is capable of acquiring a signal with a frequency error of up to ±100 kHz.
4.9 Bit Error Rate
The RDMS™ meets the following BER limits, when tested with a signal source, which complies with IRIG 106
-17.
Table 11
: RDMS™ BER Specifications
BER
Maximum E
b
/N
0
(dB)
PCM/FM, Tier 0
SOQPSK-TG, Tier I
Multi-h CPM, Tier II
10
-3
7.5
9.5
11.0
10
-4
9.0
11.5
12.5
10
-5
10.0
13.0
13.5
10
-6
11.0
14.5
14.5
Typical BER performance, plotted in Figure 48, is significantly superior to that tabulated above.