![Quantum SuperLoader 3A Series User Manual Download Page 90](http://html.mh-extra.com/html/quantum/superloader-3a-series/superloader-3a-series_user-manual_770658090.webp)
Chapter 5 Troubleshooting
On-board Remote Management Diagnostic Tests
Quantum SuperLoader 3A Series User’s Guide
76
On-board Remote Management Diagnostic Tests
You can perform the following diagnostic tests from On-board Remote
Management:
• Halt Test
• Loader—Self Test
• Loader—Health Check
• Loader—Picker Test
• Loader—Magazine Test
• Loader—Inventory Test
Diagnostics Using On-
board Remote
Management
5
Many tests can be run using On-board Remote Management. To perform
On-board Remote Management diagnostic tests:
1
Open a web browser and connect to the autoloader. The On-board
Remote Management main menu displays.
2
Click the
Diagnostics
heading. A login window displays.
3
Type an
Administrator
user name and a password, and then click
Enter
.
The
Diagnostics
submenu displays.
4
Select the test you wish to perform from the Diagnostics drop-down
menu, and then click
Start Test
.
The selected diagnostic test runs. While the test is running, you can
view the status of the test. To view the status from the
View
Diagnostic Test Progress
, click
View Status
.
Note:
On-board Remote Management allows you to request all
diagnostic tests, but any tests that require a cartridge to be
inserted will time-out unless someone manually inserts the
cartridge at the appropriate time.