UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9
User’s Guide 292/1523
This command sets the Edgeport BPDU Guard enable/disable parameter for accepting BPDUs on this
switch. This command only works on dot1d mode.
Syntax
spanning-tree edgeport bpduguard
no spanning-tree edgeport bpduguard
no -
This command sets the Edgeport BPDU Guard to the default value, that is, Disabled.
Default Setting
Disabled
Command Mode
Global Config
This command sets the Edgeport BPDU Filter enable/disable parameter for sending/receiving BPDUs
on this interface. This command only works on dot1d mode.
Syntax
spanning-tree bpdufilter
no spanning-tree bpdufilter
no -
This command sets the Edgeport BPDU Filter to the default value, that is Disabled.
Default Setting
Disabled
Command Mode
Interface Config