6.12.2.7
lldp timers
This command is used to set the timing parameters for local data transmission on ports enabled for
LLDP. The <interval-seconds> determines the number of seconds to wait between transmitting local
data LLDPDUs. The range is 1-32768 seconds. The <hold-value> is the multiplier on the transmit
interval that sets the TTL in local data LLDPDUs. The multiplier range is 2-10. The <reinit-seconds> is
the delay before re-initialization, and the range is 1-0 seconds.
Syntax
lldp timers [interval <interval-seconds>] [hold <hold-value>] [reinit <reinit-seconds>]
no lldp timers [interval] [hold] [reinit]
<interval-seconds> -
Configures the number of seconds to wait between transmitting local data
LLDPDUs
<hold-value> -
Configures the multiplier on the transmit interval that sets the TTL in local data
LLDPDUs
<reinit-seconds> -
Configures the delay before re-initialization
no -
This command is used to return any or all timing parameters for local data transmission on ports
enabled for LLDP to the default values.
Default Setting
Interval-seconds 30
Hold-value 4
Reinit-seconds 2
Command Mode
Global Config