7.7.2.3
ip irdp holdtime
This commands configures the value, in seconds, of the holdtime field of the router advertisement sent
from this interface.
Syntax
ip irdp holdtime < maxadvertinterval-9000 >
no ip irdp holdtime
<
maxadvertinterval-9000 >
The range is the maxadvertinterval to 9000 seconds.
no -
This command configures the default value, in seconds, of the holdtime field of the router
advertisement sent from this interface.
Default Setting
The default value is 3* maxadvertinterval (600) =1800.
Command Mode
Global Config
7.7.2.4
ip irdp maxadvertinterval
This commands configures the maximum time, in seconds, allowed between sending router
advertisements from the interface.
Syntax
ip irdp maxadvertinterval < minadvertinterval-1800 >
no ip irdp maxadvertinterval
<
minadvertinterval-1800 > -
The range is 4 to 1800 seconds.
no -
This command configures the default maximum time, in seconds.
Default Setting
The default value is 600.
Command Mode
Global Config