Interfaces
7-4
Paper Instruction (PI)
- Optional EVFU control signal from the host with the same timing as
the data lines. Sensing the PI line is controlled by printer configuration.
NOTE: The PI Line must be disabled (configuration option selected from the front
panel) if the host computer does not drive or control the PI Line. If the line is not conĆ
trolled by the host and sensing is enabled, rapid paper slewing will occur.
Table 7-2. Centronics Interface Connector Pin Assignments
INPUT SIGNALS
OUTPUT SIGNALS
SIGNAL
PIN
SIGNAL
PIN
Data Line 1
Data Line 2
Data Line 3
Data Line 4
Data Line 5
Data Line 6
Data Line 7
Data Line 8
Paper Instr.
Data Strobe
Return
Return
Return
Return
Return
Return
Return
Return
Return
Return
ACKNLG
SLCT/IONL
+5 Volts
Busy
Chassis
Not Used
Return
Return
PE
(Test Only)
Ground
2
20
3
21
4
22
5
23
6
24
7
25
8
26
9
27
15
14
1
19
10
28
32,13
12
18
11
29
16,17
33
30,31,
34,35, 36
Parallel Interface Configuration
The printer is configured at the factory for the type of interface used, either parallel or serial.
However, certain user selectable configuration options are available. The following configuraĆ
tion parameters can be verified or changed as necessary to meet specific application requireĆ
ments:
n
Input buffer size
n
Sense of Data Line 8
n
Sense of the Paper Instruction line
n
Data Polarity
n
Printer Error Polarity
n
Fast Busy
These parameters are displayed under the Application Compatibility and Interface CompatiĆ
bility menus selectable from the control panel. This data may be latched on either the leading
or the trailing edge of the Data Strobe signal by selecting the appropriate jumper on the Logic
Summary of Contents for P6000L
Page 1: ...P600L P6200L Line Printers User s Reference Manual R...
Page 2: ......
Page 3: ...P6000L P6200L Line Printers User s Reference Manual R P N 140576 001 Rev C...
Page 20: ...Overview 1 6...
Page 28: ...Operation 2 8 Figure 2 4 Paper Adjustment Controls Floor Cabinet Model...
Page 34: ...Operation 2 14 Figure 2 10 Loading Paper...
Page 51: ...3 7 Configuration Figure 3 1 Sample Configuration Printout...
Page 56: ...Configuration 3 12 Figure 3 4 PCBA Removal Pedestal Model Printer...
Page 100: ...Vertical Format Units 5 16...
Page 167: ...7 9 Interfaces Figure 7 1 Alternate Terminating Resistor Location Floor Cabinet Model...
Page 169: ...7 11 Interfaces Figure 7 2 Alternate Terminating Resistor Location Pedestal Model...
Page 190: ...RibbonMinder 9 14...
Page 200: ...Installation 10 10 Figure 10 9 Side Shock Mount Restraint Screw Removal Floor Cabinet Model...
Page 202: ...Installation 10 12 Figure 10 10 Pedestal Legs Installation Pedestal Model...
Page 206: ...Installation 10 16 Figure 10 14 Shipping Restraint Removal Pedestal Model...
Page 208: ...Installation 10 18 Figure 10 16 Cable Connections Pedestal Model...
Page 210: ...Installation 10 20...
Page 212: ...Appendix A 2...
Page 213: ...B 1 Appendix APPENDIX B Serial Emulation Mode Character Set 1 80 9F Control Codes...
Page 214: ...Appendix B 2 Serial Emulation Mode Character Set 2 80 9f Printable Symbols...
Page 215: ...B 3 Appendix P Series Mode Character Set 1 80 9f Control Codes...
Page 216: ...Appendix B 4 P Series Mode Character Set 2 80 9f Printable Symbols...
Page 217: ...B 5 Appendix International Characters...
Page 218: ...Appendix B 6...
Page 232: ...P6000L P6200L User s Reference Manual Index 6...
Page 233: ......