Operation and installation manual
Page 45 of 82
(PVI-10.0/12.5-OUTD-xx Rev:1.2)
Message Error
Warning
Error
Type
Description
Sun Low
W001
//
Input Voltage under threshold
Input power below threshold (when off)
Input OC
//
E001
Input Overcurrent
Input UV
W002
//
Input Undervoltage
Input OV
//
E002
Input Overvoltage
Int.Error // E003
No
parameters
No parameters
Bulk OV
//
E004
Bulk Overvoltage
Int.Error // E005
Communication
Error
Communication Error
Out OC
//
E006
Output Overcurrent
Int. Error
//
E007
IGBT Sat
Sun Low
W011
//
Bulk Undervoltage
Int.Error // E009
Internal
Error
Internal Error
Grid Fail
W003
//
Grid Fail
Grid parameters incorrect
Int.Error // E010
Bulk
Low
Int.Error // E011
Ramp
Fail
DC/DC Fail
//
E012
DcDc Error revealed by inverter
Inverter detected a DcDc failure
Wrong Mode
//
E013
Wrong Input setting (Single instead of dual)
Wrong input setup (single instead of dual)
Over Temp.
//
E014
Overtemperature
Excessive internal temperature
Cap. Fault
//
E015
Bulk Capacitor Fail
Bulk capacitors fault
Inv. Fail
//
E016
Inverter fail revealed by DcDc
Inverter failure
detected by DcDc
Int.Error // E017
Start
Timeout
Ground F.
//
E018
I leak fail
Leakage current error
l