Installation & Operation Manual TCC70XS
Page 97
Manual
Clicking
Update Now!
forces a manual update with the real
–
time reference. All changes at
this configuration page will immediately get effective
–
provided that the real
–
time reference
currently delivers valid data.
Mode of Local Time Zone Synchronization
Periodically
The internal real
–
time clock updates periodically with the time & date reference according to
the following programming:
Mode
Off
No periodically update.
Every Second
Update every second.
Every Day
Update once a day, at the selected
Hour
.
Every Week
Update once a week, at the selected
Day of Week
and
Hour
.
Every Month
Update once a month, at the selected
Day
and
Hour
.
Every Year
Update once a year, at the selected
Month
and
Day
and
Hour
.
Settings
Day
,
Day of Week
,
Month
and
Hour
become active dependent on the “Mode“
selection.
At Special Events
Additionally, to the moments selected at
Periodically,
an update with the time & date
reference can be programmed at special events:
Reference Lock within 20 min
: Due to the nature of some real
–
time sources it may last
some minutes after power has turned on until a “Lock“ status will be indicated. The
module can be set to monitor this status for a 20 minutes period after power
–
on,
and as soon as “Lock” has been detected an update occurs again. There is a risk
of generating a time jump caused by this update. If you don’t need this feature,
uncheck this checkbox. The
“Lock“ status has to be part of the status data received
from the real
–
time reference.
After DST Switching of Reference Input
: Check this checkbox to force an additional update
when the real
–
time reference switches the time zone (start or end of DST). The DST
switching has to be announced in the status data of the reference input.
Please refer to chapter “
Handling of a
DST Switching” as well.
After Leap Second of Reference Input
: Check this checkbox to force an additional update
when the real
–
time reference will be corrected through a leap second. The leap
second adjustment has to be announced in the status data of the real
–
time
reference input.
Please refer to chapter “
Handling of a
Leap Second” as well.