Wheel
Number of frames for the drop
–out compensation in the “
Cont.
Wheel” mode.
Use Offset
If checked a programmed offset will be added to the time of read time code.
A negative offset can be achieved as follows: subtract the time or the number of frames by
which the output should be delayed with respect to the input from 24 hours
–
considering the
current frame rate. Example: for a delay of 10 frames in a 30 frames system choose an offset
of 23:59:59:20.
Offset
You can program a “hours:minutes:seconds:frames” offset.
Via USB you have to press the
tabulator key
at the PC’s keyboard to store the offset,
via
Browser press the
Save To Module
button.
Ignore “Read Offset”
This concerns the “Read Offset to 00:00:00:00” and “Read Offset to 10:00:00:00” operation
modes switched on by a programmed function key or a programmed GPIO.
If checked:
The generator receives and generates the original reader values, regardless
of the “Read Offset” function. If any “Read Offset” operating mode is
switched on, the generator values will then be different from the processed
reader values.
If not checked:
If any “Read Offset” operatin
g mode is switched on, the generator will
receive and generate these processed reader values.
The offset entered at this configuration page will be added to the values transferred from the
reader
–
independent from clicking this checkbox or not.
Single Jam
This method will switch from JAM SYNC to START operating mode automatically as soon as
the time code generator has once received data from the reader. If
–
according to the set
–
up
at “Values” –
a time transfer has been selected, the time addresses of the generator will be
set by the time addresses of the read time code only once; after that the time will be counted
continuously. If TCC70XS has been switched off, the “Single Jam” method will be cleared.
Single Jam
can be activated by a click on this button, or by a programmed function key or a
programmed GPIO.