3.2.8.3 NTP Status and Troubleshooting
The NTP server indicates its status at the “Stratum” and “Reference” fields.
Refer to the following table to interpret the given information:
Stratum: 0
Reference: INIT
The internal real
–
time clock has not received any valid time update since power has turned
on.
This state sets an alarm condition in the NTP message:
LI
= 3 = clock not synchronized.
Possible causes if “Reference –
Source = External PPS + Serial
“ has been selected at the
Reference
configuration page of the 3G
–
Video module:
•
The external real
–
time reference is not connected,
•
or does not send valid data,
•
or the serial protocol does not match the protocol selected at “Reference –
Format“ at
the
Reference
configuration page of the 3G
–
Video module.
Possible causes if “Reference –
Source = NTP Client“ has been selected at the
Reference
configuration page of the 3G
–
Video module:
•
The NTP client is disabled (checkbox
enable
at the
NTP Client
configuration page of
the Ethernet module must be checked),
•
or the NTP client cannot connect to an NTP server (verify the IP addresses).
The status monitor of the 3G
–
Video module offers further help with its
Time and Date
page:
at
external reference
status “
connected before
“ and “
accepted before
“ indicate
s whether a
valid time & date has been received at all.
Stratum: 1
Reference: GPS
Normal operating mode. The real
–
time method of operation works faultless. The internal
real
–
time clock has received an update during last 24 hours by a reference which indicates
“Lock” state
and
the frequency and phase synchronization of the time code generator works
normal.
[Stratum = 1 requires setting “Fudge Stratum“ to 1]
Stratum: > 1
Reference: 0.0.0.0
“Reference“ will be set to “0.0.0.0“ for any stratum values > 1.
There are various possible
causes for a stratum > 1:
A
Fudge Stratum
set to > 1 (please refer to chapter “NTP Server“). In this case the stratum