Installation & Operation Manual TCC70XS
Page 93
Date+Status
[S
H
S
L
.DD.MM.YY]
BCD coded date: Day.Month.Year [BG6/5 . BG4/3 . BG2/1]; two-digit year format.
S
H
S
L
indicate a status:
Bit(s)
S
L
= BG7 (“Units of Hours“):
0
If = 1: Time code transports the local time with high precision.
1+2
Time zone: Bit 2 Bit 1
0
0 = UTC
0
1 = Standard Time
1
0 = Daylight Saving Time
3
If = 1: Announcement of DST switching, one hour before switching.
Bit(s)
S
H
= BG8 (“Tens of Hours“):
0
If = 1: Announcement of a leap second, one hour before switching.
1
Century bit, should be equal to 0.
2
Not used, should be equal to 0.
3
Not used, should be equal to 0.
BBC
Date coded according to the “EBU Technical Information I29–1995” (so–
called BBC
format). The date is BCD coded and assigned to the binary groups as follows:
BG1
Reserved
All bits = 0
BG2
Units of the day
4 bits, LSB = bit 12
BG3
Units of the month
4 bits, LSB = bit 20
BG4
Tens of the day
2 bits, LSB = bit 28
Tens of the month
1 bit = bit 30, bit 31 = 0
BG5
Reserved
All bits = 0
BG6
Units of the year
4 bits, LSB = bit 44
BG7
Reserved
All bits = 0
BG8
Tens of the year
4 bits, LSB = bit 60
Date: DD.MM.YY.YY
BCD coded date: Day.Month.Year [BG8
–
7 . BG6
–
5 . BG4
–
1]; four-digit year format.
Date: YY.MM.DD.UU
Date: UU.YY.MM.DD
Date: UY.YM.MD.DU
Date: DD.MM.YY.UU
Date: MM.DD.YY.UU
Date: UU.MM.DD.YY
There are several date formats selectable similar to the „
Date: UU.DD.MM.YY“
format. Please refer to this table for a survey:
BG8/7 BG6/5 BG4/3 BG2/1
UU.DD.MM.YY
U U
DD
M M
YY
Date + Status
S
H
S
L
DD
M M
YY
DD.MM.YY.YY
DD
M M
YY
YY
YY.MM.DD.UU
YY
M M
DD
U U
UU.YY.MM.DD
U U
YY
M M
DD
UY.YM.MD.DU
U Y
Y M
M D
D U
DD.MM.YY.UU
DD
M M
YY
U U
MM.DD.YY.UU
M M
DD
YY
U U
UU.MM.DD.YY
U U
M M
DD
YY