Installation & Operation Manual TCC70XS
Page 127
Step 2:
Configuration page
Read
(3G
–
Video module):
Choose
priority “High“ for
LTC Read
(or for the
reader of that time code format which
transports the MTD data),
priority “
Off
“ for all other time code readers,
“MTD –
Source =
Read
“,
“User
–
Mode =
MTD Data
“.
Selection at “
MTD
–
Insert” adjusts the video
window of the MTD timer:
Align Left
Left adjusted
Align Right
Right adjusted
Fixed Size
Window fixed to maximal width
Step 3:
Configuration page
Video
(3G
–
Video module):
You have to check
Insert Enable
to let all
programmed video windows become visible!
Step 4:
Configuration page
Insert
(3G
–
Video module):
Choose
a window and click
Visible
,
“Source =
Read
“,
“Format =
MTD Time A
“ or any other MTD
timer as you like. If you want to insert the MTD
date, select “Format =
Date, DD MM YYYY
“ or
any other “
Date
“ format.
Any other parameter can be selected freely.