Installation & Operation Manual TCC70XS
Page 122
Configuration page
Time Zone
:
Reference Input
: If the real
–
time reference
does not deliver UTC, select the time zone of
the reference from the
Preset
list and click
Load
, or enter the offsets manually.
Local Time Zone
: Select the local time zone
from the
Preset
list and click
Load
or enter
the offsets and the parameters of a DST
switching manually.
Configuration page
Reference
:
Reference
Source
:
“
External PPS + Serial
“
or
“
NTP Client
“.
Format
:
If “
External PPS + Serial
“
is set:
you have to select the serial protocol which
must conform to the protocol used from
the real
–
time reference.
Time Zone and DST Mode
Reference Input
: “
Auto
“.
Local Time Zone
: “
Auto+ Reference Check
“,
if the local time zone utilizes a daylight-
saving time (DST).
“
UTC+ Reference Check
“,
if no daylight-
saving time is in effect.
Please adjust all other parameters as shown.
Configuration page
Keys
(recommended):
Key F1 =
Operating Mode Real
–
Time
.
Key F2 =
Operating Mode Free
.
Status
Reference Input
: Lights up if the unit
receives and accepts signals of a real
–
time
reference.
Status
Reference Lock
: Indicates the status
of the real
–
time reference.
Status
Gen Sync Status
: Feedback of the
phase and frequency synchronization.
Status
Clock Free Run
: Indicates the
precision of the internal real
–
time clock.