Installation & Operation Manual TCC70XS
Page 74
connected before
= “
yes
“, as soon as data of the real–
time reference has been
received
–
without a check of plausibility. This status returns to “
no
“
every time the REAL
–
TIME method of operating is switched on or the
source of the real
–
time reference or the serial protocol has changed.
accepted before
= “
yes
“, as soon as valid time & date data of the real–
time
reference has been received once. This status returns to “
no
“ every
time the REAL
–
TIME method of operating is switched on or the
source of the real
–
time reference or the serial protocol has changed.
sync after reset
This status is part of the data of the real
–time reference: “
yes
“, as
soon as the real
–
time reference itself has synchronised.
locked
This status is part of the data of the real
–
t
ime reference: “
yes
“, if the
real
–
time reference currently is synchronised.
local time zone:
Status information about the internal real
–
time clock.
time
Current time of the internal real
–
time clock.
date
Current date of the internal real
–
time clock.
ext/int difference
Time difference between time of the internal real
–
time clock and the
time of the real
–
time reference converted to the local time.
If
“
Auto + Reference Check
“ or “
UTC + Reference Check
“
has been
selected at “
Time Zone and DST Mode
–
Local Time
Zone“
at config-
uration page
Reference
, the time of the real
–
time reference will be
checked. If there is a difference of one minute or more, the time will
be considered as invalid and the
ext/int difference
calculation stops.
day dst start/end
DST switching is based on a fixed algorithm (please refer to chapter
“Time Zone: Time Zone Adjustment“). The month of a switching is
set by configuration; the day has to be calculated with respect to the
current year. The result is displayed for control purposes.
Example for year 2014: Start of DST at last Sunday of March = 30
th
;
end of DST at last Sunday of October = 26
th
.
sync after reset
Status of the internal real
–
time clock
: “
yes
“, as soon as the internal
real
–
time clock has been set after power has turned on either by the
real
–
time reference or manually.
locked
Status of the internal real
–
time
clock: “
yes
“, if
the internal real
–
time
clock has high precision. This requires an update within the last 24
hours with time & date of the real
–
time reference. The real
–
time
reference must have indicated
“lock” state at that moment.
internal utc:
Status of the internal time base (calculated time zone = UTC).
time
Current time of the calculated UTC.
date
Current date of the calculated UTC.